AAA10F介紹
高壓功率監(jiān)視器(HVPM)是Monsoon最新的功率測(cè)量?jī)x器??赏耆娲淝按a(chǎn)品FTA22D,高壓功率監(jiān)視器支持主通道輸出電壓范圍0.8V至13.5V和高達(dá)6A的連續(xù)電流。這擴(kuò)展了高壓電源監(jiān)控器支持的設(shè)備范圍,從移動(dòng)設(shè)備擴(kuò)展到筆記本電腦、平板電腦、汽車(chē)設(shè)備、原型電子產(chǎn)品,手機(jī),智能手表等物聯(lián)網(wǎng)設(shè)備。除了主通道外,它還支持通過(guò)USB和輔助通道進(jìn)行高達(dá)5.5V的外部輸入。HVPM依然是一個(gè)兼?zhèn)潆娫春碗娏鳒y(cè)量設(shè)備,它提供了方便的二合一功能,而全自動(dòng)支持您的任何編程需求。
PowerTool軟件和Power Monitor硬件為移動(dòng)設(shè)備提供了強(qiáng)大的功率測(cè)量解決方案。PowerTool軟件和Power Monitor硬件可以分析設(shè)備的功耗。電氣工程師和軟件開(kāi)發(fā)人員可以利用PowerTool軟件和Power Monitor硬件來(lái)優(yōu)化設(shè)計(jì)并分析其移動(dòng)設(shè)備的性能。
高壓電源監(jiān)控器通過(guò)UL、FCC和CE認(rèn)證。它適用于需要一到三個(gè)鋰離子電池供電的設(shè)備。
每臺(tái)儀器都配有一個(gè)定制設(shè)計(jì)的電源、2個(gè)鱷魚(yú)夾、3條USB電纜和一個(gè)信息卡,其中包含軟件下載和支持文檔的鏈接。
相比其他產(chǎn)品,顯著優(yōu)點(diǎn):
1.精度高。支持50uA的測(cè)量精度,通過(guò)波形可看到10幾到20uA的測(cè)量精度。
2.支持自動(dòng)化測(cè)試。Power Monitor可結(jié)合機(jī)械手對(duì)所需測(cè)量的設(shè)備進(jìn)行長(zhǎng)達(dá)數(shù)周的連續(xù)測(cè)試。
3.產(chǎn)品觸發(fā)功能。開(kāi)發(fā)人員可用Power Monitor 對(duì)被測(cè)試設(shè)備設(shè)置進(jìn)行所需要指定條件進(jìn)行采樣,Power Monitor 只記錄指定條件的采樣數(shù)據(jù),這樣大大節(jié)省了開(kāi)發(fā)人員的時(shí)間和精力。
我司是該產(chǎn)品授權(quán)代理商,官網(wǎng)可查,代理證書(shū):
主要產(chǎn)品參數(shù):
最大輸出電壓:13.5V
最大持續(xù)電流:6A
最大輔助輸入電壓:5.5V
具體產(chǎn)品參數(shù):
The PowerTool software and the Power Monitor hardware provide a robust power measurement solution for mobile devices. The PowerTool so ftware and the Power Monitor Hardware can analyze the power On any device that uses up to a 3-cell Lithium-Ion Battery, supplying up to 13.5V and 6 Amps. Electrical engineers and software developers can utilize the PowerTool software and the Power Monitor hardware to optimize the design and analyze the performance of their mobile devices.
Figure 1 Graphical user interface (GUI) for the PowerTool software
The Power Monitor can measure data on three channels: Main, USB, and Auxiliary. The Main channel is what most users will use for their measurements. A USB channel is provided as is an AUX channel . The GUI details are described below for the Main channel, but largely apply to all sampling sources. Cases where they differ are called out in the appropriate sections on USB or AUX measurements.
Figure 2 Mobile Device Power Monitor
A dedicated Windows plat Form workstation is required to be used with the Power Monitor to achieve the optimal performance and results. Slower/older computers may not be able to process samples efficiently enough and users may see a significant number of dropped samples.
ξ Windows Vista, Windows 7, Windows 8, or Windows 10 [XP support discontinued after 4.0.4.11]
ξ 1024x768 or greater screen resolution
ξ 3.2 GHz 32-bit (x86) processor.
ξ 4 GB of system memory
ξ 40 GB hard drive with at least 15 GB of available space
ξ Version 4.0.4.12 and 5.0.0.0 require .Net 4.5. Version 4.0.4.11 requires .Net 4.0. Versions 4.0.4.0-4.0.4.10 require .Net 3.5.
ξ Full Speed USB 2.0 ?integrated chipset or PCI/PCI Express add in card.
ξ USB 3.0 or Downstream Charging ports are recommended for Front-panel connections.
USB Hubs, including monitor hubs, should not be used with the Power Monitor for optimal performance.
Prior to installing the latest version, uninstall any previous version of the Power Monitor Software from the Control Panel.
Create a new temporary folder on the development workstation under the root directory
(C:\).
Copy PowerTool.zip to the Development workstation.
Extract the contents of PowerTool 5.X.X.X.zip to the temporary folder.
Run PowerTool Install.exe
Follow the on screen prompts to install the PowerTool Software.
After the PowerTool application has been installed and this is the first time the workstation
will be running the PowerTool application you will need to install two drivers, the Power
Monitor driver and the Firmware driver. Instructions are as follows:
1.Power on Power Monitor in normal mode ?Green led should be on.
2.Under Device Manager, find Mobile Device Power Monitor ?will have a yellow exclamation mark.
3.Right click and select Update Driver Software?
4.Select Browse my computer for driver software
5.Browse to C:\Program Files (x86)\Monsoon Solutions Inc\PowerMonitor\Drivers\PC and click on Next.
6.Click on Close once the driver has finished installing.
7.Under Device Manager ?Universal Serial Bus devices, ensure that the Mobile Device Power Monitor has enumerated properly.
1. Power on the Power Monitor in Output Enable mode by depressing the Output Enable button and the Power button simultaneously ?Amber led should be on.
2.Under Device Manager find the Unknown device and right click, select Update Driver Software?
3. Select Browse my computer for driver software
4. Browse to C:\Program Files (x86)\Monsoon Solutions Inc\PowerMonitor\Drivers\Firmware and click on Next
5. Click on Close once the drive has finished installing.
6. Under Device Manager ?Custom USB Devices verify that the Microchip Custom USB Device has enumerated properly.
The Power Monitor is shipped with the latest firmware and in most cases will not be required to be updated. If for any reason the firmware does need to be updated use the following instructions.
Power on the Power Monitor in Output/Enable mode by pressing on the Output Enable button and Power button simultaneously. The amber light should be on.
Figure 3 Output Enable button
Start the PowerTool application, and select the Reflash option, which is enabled whenever a Power Monitor device in boot mode is detected.
Figure 4 PM Flash Select Option
Click on the Load button and browse to the PMFlash folder where the PowerTool application
was installed and select the PM_RevX_ProtXXVerXX_Boot.fwm file. (Note, X is a placeholder for the proper version information for a given fwm file, for example,PM_RevD_Prot18_Ver21.fwm). The Reflash utility is also compatible with the deprecated .hex file format used in previous firmware releases.
Click on the Write button
Wait until the Status shows ?Write complete?.
Click on the X in the upper right of the window to exit when you are done.
Power off and then power back on the Power Monitor so you now have a green light.
Figure 5 PM Flash Window
1.Ensure to read all instructions carefully before operation. Using the Power Monitor in A manner not specified by this manual may damage the equipment and impair protections designed for user safety.
2.Be sure that the power switch on the front of the Power Monitor hardware is not engaged. The hardware should not be powered-up.
3.The power switch should be in the outward position, not the inward position.
4.Connect the supplied 16 VDC / 7.5 Amp, power supply to the back of the Power Monitor and a wall power supply matching the unit抯 input requirements (100-240V, 47-63 Hz, 1.6A Maximum)
5.The power supply should be positioned so that it is within easy reach in the event that it needs to be disconnected for safety. Ensure this by placing the power brick on the same work surface as the Power Monitor with the AC input side facing the user. Ensure there are no obstructions in the work area that may impede you in the event of an emergency.
6.On a development workstation that is compliant with Full-Speed USB 2.0, connect a USB cable to the USB connector on the back of the Power Monitor hardware, and connect the other end of the USB cable to the development workstation. Do not connect to an external USB hub device.
************************************************************
Do not connect a third party power supply to the Power Monitor. The connector used does not have a standard pinout, and an improperly selected Power Supply may damage the device. If a replacement power supply is Required, contact Monsoon Solutions.
************************************************************Figure 6 Back view: Power connector and USB connector
7.Turn on the Power Monitor hardware by engaging the power button on the front. The internal fan will briefly power-up and then power-down.
8.Initially, the power light-emitting diode (LED) is amber, and then it turns green. The green LED is connected directly to the internal power of the Power Monitor.
Figure 7 Front view: Engaged power button and powered-up green LED
Refer to the Appendix on how to properly configure a device battery to connect to the Power Monitor.
Note Wear ANSI Z87.1 compliant safety goggles at all times while working with exposed battery terminals and wiring.
**************************************************************
Connecting the Power Monitor to a device to collect current measurements can be complicated and dangerous. Be sure that the area where power measurements are being conducted is protected from fire danger, do not have flammable items
nearby. These measurements are at your own risk, and these procedures are not guaranteed to prevent damage or injury.
**************************************************************
Note When attaching the power measuremenT hardware to a device with a lithium battery, there is always a risk of damaging the device, or causing the device to heat-up, Generate smoke, or catch fire. While this is unlikely, be extremely careful. It is recommended to work on a flame-resistant surface and have fire control equipment at the ready when performing the battery bypass and connecting the Power Monitor to the device under test. Immediately disconnect equipment that begins to exceed safe temperatures.
Figure 8 A mobile device connected to the main channel
After connecting the device, power up the Power Monitor and run the PowerTool software (PowerTool.exe). The software should connect to the Power Monitor, and display the user interface (UI).
Figure 9 PowerTool software UI afTer connecting to a device
The revisions of the hardware (HW ver), firmware (FW ver), and software (SW ver) should be compatible for consistent and repeatable results and performance.
If the Power Monitor software Is updated, the firmware will need to be confirmed for compatibility. The Power Monitor will prompt the user to indicate that a new firmware is required to run this revision of software. If this occurs, then the firmware (FW ver) will need to be updated on the Power Monitor. Please follow the instructions on updating the Power Monitor firmware.
The following table describes The various revision numbers that are displayed in the UI.
Field | Description |
HW rev | Power Monitor hardware revision |
FW ver | Power Monitor firmware version |
Prot ver | Version of protocol specification |
SW ver | PowerTool UI version |
HW rev | SW ver | Firmware Version |
B, C, D | 3.0.4 | 12 |
B, C, D | 4.0.2, 4.0.1 | 17, 18 |
B, C, D | 4.0.3 | 19 |
B, C, D | 4.0.4 | 19, 20 |
D, F | 5.0.0 | 21 |
Component | Minimum | Maximum |
---|---|---|
Output voltage range | 0.8V | 13.5V |
Continuous current | 6.0A | |
Integrator cutoff frequency | 300 kHz | |
Fine current scale-range | 60mA | |
Fine current scale-resolution | 2.86uA | |
Fine current scale-accuracy | +/-1% or +/-50uA(whichever is greater) | |
Coarse current scale-range | 60mA | 6.0A |
Coarse current scale-resolution | 286uA | |
Coarse current scale-accuracy | +/-1% or +/-1mA(whichever is greater) | |
Programmable current limit range | 8mA | 15.625A |
Programmable current limit accuracy | (0.7)*(current limit) | (1.4)*(current limit) |
PTC trip limit at 16V DCIN | Not applicable | 14A |
Fan turn on temperature | 1C | 40C |
Fan turn off temperature | Fan turn on setpoint-5 | |
Thermal limit shutdown | 75C |
To make sure the correct software is installed,check the revision fields in the UI. Figure 10 below shows the area of the UI that displays the software revision.
Figure 10 Revision fields shown in the PowerTool UI
AAA10F是一個(gè)兼?zhèn)潆娫春蜏y(cè)量電流功能的設(shè)備。它的目的是作為一個(gè)電池或電源更換為您的設(shè)備,讓它記錄設(shè)備運(yùn)行期間所有的功率消耗
保修:非人為原因,所有產(chǎn)品保修一年。
技術(shù)支持:我們對(duì)儀器提供終身免費(fèi)技術(shù)支持,您遇到任何問(wèn)題,我們都會(huì)在當(dāng)天反饋的美國(guó) 原廠(chǎng),當(dāng)天即可得到技術(shù)支持。我們一定給您最準(zhǔn)確最權(quán)威的答復(fù)。
應(yīng)用范圍:購(gòu)買(mǎi)此儀器的客戶(hù)80%是測(cè)手機(jī)的電流,功耗及其穩(wěn)定性。此儀器還可以測(cè)電子元器 件上的功耗,電流電壓測(cè)試范圍是可以調(diào)節(jié)的,此儀器精度很高,測(cè)試精度可以達(dá)到微安級(jí)別,可以滿(mǎn)足絕大部分的電流功耗測(cè)試。
關(guān)于客戶(hù)范圍:我們的客戶(hù)主要覆蓋各大手機(jī)公司,包括聯(lián)想手機(jī),TCL手機(jī),華為手機(jī),中興手機(jī),360手機(jī)等。 還覆蓋各個(gè)大學(xué),研究所,包括清華大學(xué),鄭州大學(xué)等。還覆蓋各大手機(jī)方案公司等。